3516B (60 Hz) with Upgradeable Package

3516B (60 Hz) with Upgradeable Package

The3516B with the upgradeable packaging design has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance to matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.

Height - Maximum
98.2 in
Length - Maximum
234.5 in
Width - Maximum
90 in
Minimum Rating
1640 ekW

Generator Set Dimensions

Height - Maximum
98.2in
Length - Maximum
234.5in
Width - Maximum
90in

Generator Set Specifications

Minimum Rating
1640 ekW
Maximum Rating
2250 ekW
Voltage
220 to 4160
Frequency
60 Hz
Speed
1800 rpm

Generator Set Configurations

Emissions/Fuel Strategy
Low fuel Consumption, Low Emissions

Engine Specifications

Engine Model
C32 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
145 mm (5.71 in)
Displacement
32.1 L (1958.86 in3)
Stroke
162 mm (6.38 in)
Compression Ratio
15.0:1
Aspiration
TA
Governor Type
Adem™A4
Fuel System
MEUI
Exhaust Flange Size - Internal Diameter
203.2 mm (8.0 in)
Air Inlet
Single element canister style with service indicator
Displacement
1958.7in
Bore
5.71in
Stroke
6.38in

Standard Equipment:

  • Air Inlet System
    • Air Cleaner; single element canister type
  • Control Panels
    • EMCP 4.2B
    • Emergency stop pushbutton
    • 24 Volt DC operation
    • Environmental sealed front face
    • Text alarm / event descriptions
    • Generator mounted - rear facing
    • Generator set packages include:
    • Caterpillar' s voltage regulator
    • IVR includes:
    • Reactive droop capability
    • 3 Phase voltage sensing
    • KVAR/PF modes
    • RFI suppression
    • Min / max exciter
    • Limiter and exciter diode monitor
    • Controls:
    • Speed adjust
    • Auto / start / stop control
    • Engine cool
    • Alarm acknowledge
    • Lamp test
    • Load histogram feature
    • PLC functionality
    • Customizable screens
    • 0 True RMS AC metering, 3-phase, +/-2% accuracy
    • Digital indication for:
    • RPM
    • DC volts
    • Operating hours
    • Oil pressure (psi, kPa or bar)
    • Coolant temperature
    • Volts (L-L & L-N)
    • Frequency (Hz)
    • Amps (per phase & average)
    • Power Factor (per phase & average)
    • kW (per phase, average & percent
    • kVA (per phase, average & percent)
    • kVAr-hr (total)
    • Warning / shutdown with common LED indication of shutdowns for:
    • Low oil pressure
    • High coolant temperature
    • Overspeed
    • Emergency stop
    • Failure to start (overcrank)
    • Low coolant temperature
    • Low coolant level
    • Programmable protective relaying functions:
    • Generator phase sequence
    • Over / under voltage (27/59)
    • Over / under frequency (81 o/u)
    • Reverse power (kW) (32) - Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)
    • Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)
    • Overcurrent (50/51)
    • Communications:
    • Customer data link (Modbus RTU)
    • Accessory module data link
    • Serial annunciator module data link
    • Cat Connect
    • 3 Analog inputs
    • 6 Customer programmable digital inputs
    • Number of I/O varies on options selected:
    • 4 Programmable relay outputs (Form A)
  • Lubrication System
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal
    • Lubricating oil
    • Gear type lube oil pump
  • Mounting System
    • Rails - engine/generator/radiator mounting
    • Anti-vibration mounts (shipped loose)
    • Rubber anti-vibration mounts (shipped loose)
  • Starting System
    • 24 Volt electric starting motor
    • 45 Amp charging alternator
    • Battery and battery rack w/cables
    • Battery disconnect switch
  • Literature
    • English

Optional Equipment:

  • Control System
    • EMCP 4.3, EMCP 4.4
  • Air Inlet System
    • Single element filter
    • Dual element air cleaner
  • Cooling System
    • Standard ambient radiators
    • Standard ambient ATAAC radiators
    • Optional installed radiators
    • Optional installed ATAAC radiators
    • Water level switch gauges
    • Coolant
  • Crankcase System
    • No explosion relief valves
    • Explosion relief valves
    • Ventilation system
  • Exhaust System
    • Elbows
    • Flange and exhaust expanders
    • Flanges
    • Flexible fittings
    • Y-Adapters
    • Mufflers
    • Exhaust offset
    • Tier 4 clean emissions module
    • Tier 4 dosing cabinet
    • Tier 4 clean emission MOD Kits
    • Clean emission parts
  • Fuel System
    • Primary Fuel Filter
    • Fuel Priming Pumps (Tier 4) - Manual or Electric
  • General
    • US aid emblem
    • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • Generators And Attachments
    • Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
    • Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
    • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
    • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
    • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
    • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
    • Space heater
    • Generator conversion
    • Thermostat for space heater
    • Alternator air cleaner
    • Differential current transformers (DCT)
    • Differential current transformers (DCT) 8.7 kV and 15 kV classes
  • Instrumentation
    • Pyrometer and Thermocouples
  • Lubrication System
    • Lube oil in standard sump
    • Oil level regulator
    • Prelube pumps
  • Mounting System
    • Puck style low efficiency isolators
    • Spring type vibration isolators
    • IBC vibration isolators
  • Power Connections
    • Ground cables between generator and terminal box
    • Neutral ground connections
    • Center post busbar
    • Right side power connections
    • Left side power connections
    • Rear power connections
    • 2700 Frame, four lead, four terminal
    • Low voltage circuit breakers
  • Special Tests / Reports
    • Canadian Standards Association certification
    • IBC certification
    • OSHPD certification
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Standard engine test charge
    • generator test report
    • Fuel consumption test
    • Generator set fuel consumption test
    • Torsional vibration analysis reports
  • Starting And Charging
    • Engine barring device
    • 24 Volt battery set - Dry
    • 10, 20, 35 and 50 amp battery chargers
    • Electric starting motors
    • Air starting motors
    • Starter cover
    • Air pressure regulator
    • Jacket water heaters
  • Extended Service Coverage
    • Platinum, Gold and Silver coverage