XQ60

Rating
60 ekW (75 kVA) Standby
Standby Run Time (Full Load)
30+ Hours
Prime Run Time (Full Load)
32+ Hours
Model
C4.4

Generator

Rating
60 ekW (75 kVA) Standby
Standby Run Time (Full Load)
30+ Hours
Prime Run Time (Full Load)
32+ Hours
Prime Rating
54 ekW (67.5 kVA)
Voltage
208 - 480 V
Frequency
60 Hz
Rating
60 ekW (75 kVA) Standby

Engine

Model
C4.4
Type
4-cycle
Model
C4.4
Type
4-cycle

Dimensions

Width
44.5in
Height
70.9in
Length
114.2in
Weight with Lube Oil and Coolant
4431lb
Width
44.5in
Height
70.9in
Length
114.2in
Weight - With Lube Oil and Coolant
4431lb

Standard Equipment:

  • Engine
    • Heavy duty industrial EPA Tier 3 compliant diesel engine.
  • Cooling Radiator
    • Radiator and cooling fan complete with protection guards, designed to cool the engine in ambient temperatures up to 43° C (109° F).
  • Engine Filtration System
    • Cartridge type dry air filters with restriction indicator.
  • Exhaust System
    • Critical silencer with flexible connector with vertical discharge.
  • Electrical System
    • 12 volt system with 65A battery charging alternator, and starter motor.
  • Generator
    • Screen protected and drip-proof, self exciting, self-regulating brushless generator.
  • Baseframe
    • The complete generator set is mounted on a heavy duty fabricated steel baseframe.
  • Fuel System
    • Fuel feed and return lines to the engine are terminated at the baseframe mounted 24 hour extended capacity fuel tank.
  • Control Panel
    • Set mounted autostart panel in a vibration isolated NEMA 1 sheet steel enclosure with a hinged lockable door.
  • Distribution Panel
    • 3-pole UL CSA listed molded case circuit breaker mounted on the generator set in a vibration isolated NEMA 1 distribution panel.
  • Documentation
    • A full set of operation and maintenance manuals, circuit wiring diagrams, and instruction leaflets are provided.
  • Sound Attenuated Enclosure
    • A noise reducing enclosure surrounds the entire generator set. Combined with a critical engine silencer this provides an overall noise reduction from 65 to 68 dBA at 23 feet through the range.
  • Factory Tests
    • The generator set is load tested before dispatch.
  • Equipment Finish
    • All sheet metal components including the enclosure and the base tank are fully degreased, phosphated and chromated for anti-corrosive protection prior to painting with polyester powder.
  • Standards
    • The equipment meets the following standards: BS4999, BS5000, BS5514, IEC60034, EN61000-6, NEMA MG-1.22.
  • Warranty
    • Full manufacturer's warranty.

Optional Equipment: