Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Standby Rating 3500/3250/3000 kVA
Prime Power Rating 3175/2950/2725 kVA
Emissions/Fuel Strategy U.S. EPA Cert. Tier 2 / Low NOx
Voltage 380 to 11000 volts
Duty Cycle Standby, Mission Critical, Prime
Emissions/Fuel Strategy U.S. EPA Cert. Tier 2 / Low NOx
Frequency 50 Hz
Maximum Rating 3500 kVA
Minimum Rating 2725 kVA
Prime Power Rating 3175/2950/2725 kVA
Speed 1500 rpm
Standby Rating 3500/3250/3000 kVA
Voltage 380 to 11000 volts
Aspiration ATAAC
Bore 6.69in
Compression Ratio 14.0:1
Displacement 4765in³
Engine Model 3516E, V-16, 4-Stroke Water-Cooled Diesel
Fuel System Electronic Unit Injection
Governor Type Adem™ A5
Stroke 8.46in
Dry Weight - Genset (maximum) 45651lb
Dry Weight - Genset (minimum) 44930lb
Height - Maximum 131.6in
Length - Maximum 306.5in
Length - Minimum 302.6in
Width - Maximum 102.8in
Air cleaner; single element canister type
Generator set packages include:
Emergency stop pushbutton
24 Volt DC operation
KVAR / PF modes
IVR includes reactive droop capability
Cat ECS 100
Text alarm/event descriptions
Generator mounted - rear facing
Environmental sealed front face
RFI suppression
3 Phase voltage sensing
Caterpillar's voltage regulator
Min / max exciter
Limiter and exciter diode monitor
Controls:
Speed adjust
Auto/start/stop control
Engine cycle crank
Engine cool
Alarm acknowledge
PLC functionality
Customizable screens
Lamp test
Load histogram feature
Generator phase sequence
1 Programmable relay outputs (Form C)
RPM
High coolant temperature
Accessory module data link
Low coolant level
Number of I/O varies on options selected
Digital indication for:
Reverse power (kW) (32)
Reverse reactive power (kVAr) (32RV)
Overcurrent (50/51)
6 Customer programmable digital inputs
3 Analog inputs
Serial annunciator module data link
Over/under frequency (81 o/u)
Low coolant temperature
+/- 2% accuracy
Programmable protective relaying functions:
Failure to start (overcrank)
4 Programmable relay outputs (Form A)
Cat connect
Over/under voltage (27/59)
1 Programmable digital outputs
0 True RMS AC metering
3 Phase
Communications:
Overspeed
DC volts
Operating hours
Coolant temperature
Oil pressure (psi, kPa or bar)
Volts (L-L & L-N)
Power factor (per phase & average)
Frequency (Hz)
Amps (per phase & average)
kW (per phase, average & percent)
kVA (per phase, average & percent)
kVAr (per phase, average & percent)
Low oil pressure
kVAr-hr (total)
kW-hr (total)
Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
ATAAC - 3516E package radiators shipped installed
Certified standard PGS provided
Dry exhaust manifold
Flanged faced outlet(s)
Fuel cooler; not included with packages without radiator
Secondary fuel filters
Flexible fuel lines - shipped loose
SAE standard rotation
Flywheel and flywheel housing - SAE No. 00
Right hand servicing
Caterpillar yellow with high gloss black rails and radiator
Anti-condensation space heater
Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
3 Phase brushless, Salient pole
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
Winding temperature detectors
High voltage:
Medium voltage:
Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
NEMA standard hole pattern
6 Lead
Permanent magnet excitation (PMG)
Form wound
Busbar connections, right side extension box, bottom cable entry
ADEM A5
Parts book
Operation & Maintenance Manual
Gear type lube oil pump
Lubricating oil
Oil filter, filler and dipstick
Integral lube oil cool
Oil drain lines and valve
Fumes disposal
Rails - Engine/generator/radiator mounting
Anti-vibration mounts (shipped loose)
Rubber anti-vibration mounts - shipped loose
24 Volt electric starting motor
45 Amp Charging alternator
Battery and battery rack w/cables
Battery disconnect switch
EMCP 4.4
Single element filter
Dual element air cleaner
Standard ambient ATAAC radiators
Water level switch gauges
Optional installed ATAAC radiators
Coolant
Optional installed radiators
Standard ambient radiators
Ventilation system
Explosion relief valves
No explosion relief valves
Y Adapters
Primary fuel filter
Fuel priming pumps (Tier 4) - Manual or electric
US aid emblem
Special paint (Colors other than Caterpillar yellow or high performance paints)
Thermostat for space heater
Alternator air cleaner
Differential current transformers (DCT) 8.7 kV and 15 kV classes
Generator conversion
Space heater
Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
Pyrometer and thermocouples
Lube oil in standard sump
Prelube pumps
Oil level regulator
Puck style low efficiency isolators
Spring type vibration isolators
IBC vibration isolators
Neutral ground connections
Center post busbars
Right side power connections
Generator set fuel consumption test
Torsional vibration analysis reports
PGS Test report @ 0.8 power factor
IBC Certification
PGS Test report @ 1.0 power factor
Canadian Standards Association certification
Standard engine test charge
Generator test report
Fuel consumption test
OSHPD Certification
Air pressure regulator
Jacket water heaters
Air starting motors
24 Volt battery set - Dry
Starter cover
Engine barring device
10, 20, 35 and 50 Amp Battery chargers
Electric starting motors
Platinum, Gold and Silver coverage