C1.5 Generator Set

Bore
3.3 in
Displacement
91.3 in3
Stroke
3.5 in
Fuel System
Indirect Injection

Engine Specifications

Bore
3.3in
Displacement
91.3in3
Stroke
3.5in
Fuel System
Indirect Injection
Fuel System
Indirect Injection
Bore
3.3in
Displacement
91.3in³
Stroke
3.5in
Engine Model
Cat® C1.5
Compression Ratio
22.5:1
Governor Type
Mechanical
Aspiration
Naturally Aspirated

Generator Set Specifications

Minimum Rating
12.0 ekW
Maximum Rating
13.2 ekW
Voltage
110 to 415 Volts
Frequency
60 Hz
Speed
1800 rpm
Emissions/Fuel Strategy
R96/EUIIIa Equivalent
Duty Cycle
Standby, Prime

Generator Set Dimensions

Height - Maximum
41.5in
Length - Maximum
55.1in
Width - Maximum
24.4in

Standard Equipment:

  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Control Panel
    • GCCP 1.3
  • Cooling System
    • Radiator and cooling fan with guards
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
  • Exhaust System
    • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Base, formed steel with single wall integral 8-hour fuel tank
    • Standard open set fuel tank/base supplied
  • Generators And Generator Attachments
    • Voltage regulator (single phase sensing)
    • IP23 Protection
    • Segregated low voltage (AC/DC) wiring panel
    • Tower panel, IP22, bottom cable entry
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • 12 Leads
  • Governing System
    • Mechanical governing system
  • Lube System
    • Oil drain line with valve
    • Lubricating oil
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • includes lifting provisions and termination points for coolant
  • Starting / Charging System
    • 12 Volt battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Alternator Options
    • Coastal insulation protection
  • Certificates
    • Global certification for CIS
    • European upgrade to STD set for CE certificate
  • Circuit Breakers
    • Padlockable breaker device
    • 4 Pole Circuit breaker
  • Control Panel Options
    • Emergency stop with key
    • Volt free contacts for genset running
    • Battery charger
    • Volt free contacts for common alarm
    • GCCP 1.3
  • Cooling System
    • Coolant heater
  • Enclosures
    • Sound attenuated enclosure (GALV)
    • Single point lift for enclosure
  • Fuel System
    • Low fuel level alarm
    • DEFRA bunded fuel tank
    • 1000 Hr extended service interval
    • Fuel transfer control
    • Skidbase for open sets
    • Base feet
    • Skidbase for enclosures
  • Mounting Options
    • Silencer installation kit
    • Industrial silencer removal
    • Battery removal
  • Special Test And Inspection
    • PGS Test report @ 1.0 power factor
  • General
    • Packing case - canopied set
    • Packing Case - compact set
    • Radiator stone guard