C1.5 Generator Set

Bore
3.3 in
Displacement
91.3 in3
Stroke
3.5 in
Fuel System
Indirect Injection

Engine Specifications

Bore
3.3in
Displacement
91.3in3
Stroke
3.5in
Fuel System
Indirect Injection
Fuel System
Indirect Injection
Bore
3.3in
Displacement
91.3in³
Stroke
3.5in
Engine Model
Cat® C1.5
Compression Ratio
22.5:1
Governor Type
Mechanical
Aspiration
Naturally Aspirated

Generator Set Specifications

Minimum Rating
10.0 kVA
Maximum Rating
13.5 kVA
Voltage
110 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Emissions/Fuel Strategy
R96/EUIIIa Equivalent
Duty Cycle
Standby, Prime

Generator Set Dimensions

Height - Maximum
41.5in
Length - Maximum
55.1in
Width - Maximum
24.4in

Standard Equipment:

  • Exhaust System
    • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
  • Control Panel
    • EMCP 4.1
  • Cooling System
    • Coolant drain line with valve
    • Caterpillar extended life coolant
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Fuel System
    • Base, formed steel with single wall integral 8-hour fuel tank
    • Standard open set fuel tank / base supplied
  • Generators And Generator Attachments
    • Segregated low voltage (AC/DC) wiring panel
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • IP23 Protection
    • 12 Leads
    • Tower panel, IP22, bottom cable entry
    • Voltage regulator (single phase sensing)
  • Governing System
    • Mechanical governing system
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • includes lifting provisions and termination points for coolant
  • Starting / Charging System
    • 12 Volt battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Alternator Options
    • Coastal insulation protection
  • Certificates
    • European upgrade to STD set for CE certificate
    • Global certification for CIS
  • Circuit Breakers
    • 4 Pole circuit breaker
    • Pad-lockable breaker device
  • Control Panel Options
    • Volt free contacts for common alarm
    • Volt free contacts for genset running
    • Emergency stop with key
    • Battery charger
    • EMCP 4.2
  • Cooling System
    • Coolant heater
  • Enclosures
    • Sound attenuated enclosure (GALV)
    • Single point lift for enclosure
  • Fuel System
    • Low fuel level alarm
  • Mounting Options
    • Industrial silencer removal
    • Silencer installation kit
    • Battery removal
  • Special Test And Inspection
    • PGS test report @ 1.0 power factor
  • General
    • Radiator Stone Guard
    • Packing Case - compact set
    • Packing case - canopied set