C2.2 Generator Set

Bore
3.3 in
Displacement
135.2 in³
Stroke
3.9 in
Fuel System
Indirect Injection

Engine Specifications

Bore
3.3in
Displacement
135.2in³
Stroke
3.9in
Fuel System
Indirect Injection
Fuel System
Indirect Injection
Bore
3.3in
Displacement
135.2in³
Stroke
3.9in
Engine Model
Cat® C2.2, In-line 4, 4-cycle diesel
Compression Ratio
22.5:1
Governor Type
Mechanical
Fuel System
3.9in
Aspiration
Naturally Aspirated

Generator Set Specifications

Minimum Rating
13.0 kVA
Maximum Rating
22.0 kVA
Voltage
110 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Emissions/Fuel Strategy
R96/EUIIIa Equivalent
Duty Cycle
Standby, Prime

Generator Set Dimensions

Height - Maximum
43.9in
Length - Maximum
59.1in
Width - Maximum
24.4in

Standard Equipment:

  • Control Panel
    • GCCP 1.3
  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Cooling System
    • Radiator and cooling fan with guards
    • Caterpillar extended life coolant
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
  • Fuel System
    • Standard open set fuel tank / base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
  • Exhaust System
    • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
  • Generators And Generator Attachments
    • Voltage regulator (single phase sensing)
    • Segregated low voltage (AC/DC) wiring panel
    • Tower panel, IP22, bottom cable entry
    • IP23 Protection
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • 12 Leads
  • Governing System
    • Mechancial governing system
  • Lube System
    • Oil drain line with valve
    • Lubricating oil
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • includes lifting provisions and termination points for coolant
  • Starting / Charging System
    • 12 Volt battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Alternator Options
    • Coastal insulation protection
  • Certificates
    • European upgrade to STD set for CE certificate
    • Global certification for CIS
  • Circuit Breakers
    • Pad-lockable breaker device
    • 4 Pole circuit breaker
  • Control Panel Options
    • Emergency stop with key
    • Volt free contacts for common alarm
    • Volt free contacts for genset running
    • GCCP 1.3
    • Battery charger
  • Cooling System
    • Coolant heater
  • Enclosures
    • Sound attenuated enclosure (GALV)
    • Single point lift for enclosure
  • Fuel System
    • Low fuel level alarm
  • Mounting Options
    • Industrial silencer removal
    • Silencer installation kit
    • Battery removal
  • Special Test And Inspection
    • PGS test report @ 1.0 power factor
  • General
    • Packing case - compact set
    • Packing case - canopied set
    • Radiator stone guard