C4.4 Generator Set

Bore
4.13 in
Displacement
268.5 in
Stroke
5 in
Fuel System
Electronic (adjustable)

Engine Specifications

Bore
4.13in
Displacement
268.5in
Stroke
5in
Fuel System
Electronic (adjustable)
Aspiration
Turbocharged
Fuel System
Electronic (adjustable)
Bore
4.13in
Displacement
268.5in
Stroke
5in
Engine Model
C4.4, In-line 4, 4-cycle diesel
Compression Ratio
18.2:1
Governor Type
Adem™A4

Generator Set Specifications

Duty Cycle
Standby, Prime
Minimum Rating
36 ekW
Maximum Rating
60 ekW
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3

Generator Set Dimensions

Height - Maximum
53.6in
Length - Maximum
75.8in
Width - Maximum
44.1in

Standard Equipment:

  • Certificates
    • IBC Seismic and Wind Certifications
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Air Inlet System
    • Air cleaner
    • Cartridge type air filter
  • Circuit Breakers
    • Second circuit breaker box
    • 3-Pole 100% rated
    • Power perminal strips
    • Breakers (100% UL rated)
  • Control Panel
    • EMCP 4 Control panel
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank / base supplied base, formed steel with single wall integral 8-hour fuel tank
  • Cooling System
    • Coolant drain line with valve
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • Radiator stone guard
  • Generator
    • 12 Leads
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Oil drain line with valve
    • Lubricating oil
  • Control Panels
    • WCA1 Low coolant temperature alarm
    • WSS1 Low coolant level shut down
    • FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected
    • NFPA110 bundle includes:
    • PAA1 Panel mounted audible alarm
    • A coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
    • Oil temperature guage and sender
    • PBC10NU NFPA Battery Charger
    • Ground fault relay
    • Discrete I/O module
    • Volt free contacts genset run and common alarm
    • Audible alarm
    • Remote E-stop button
    • Remote annunciator
    • Low coolant temperature alarm
    • Protective devices:
    • Overload shutdown via breaker
    • Fuel level reading
    • Low coolant level shutdown
  • General
    • Engine and alternator pre-paint, Caterpillar Yellow
  • Starting/charging System
    • 24V battery with rack and cables
    • Batteries

Optional Equipment:

  • Certificates
    • IBC Seismic and Wind Certifications
  • Alternator System
    • R frame auxilliary winding
  • Air Inlet System
    • Cartridge type air filter
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Circuit Breakers
    • 3-Pole 100% rated
    • Breakers (100% UL rated)
    • Second circuit breaker box
    • Power perminal strips
  • Control Panels
    • Discrete I/O module
    • Remote annunciator
    • Remote E-stop button
    • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
    • Ground fault relay
    • Audible alarm
    • Oil temperature guage and sender
    • Volt free contacts genset run and common alarm
    • NFPA110 bundle includes: FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low Coolant level shut down - WCA1 Low Coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA Battery Charger - A coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
  • Heating Elements
    • Coolant heater
    • Battery heater
    • Anti-condensation heater
    • Lube oil sump heater
    • Jacket water heater
    • Wiring for canopy space heater
  • Cooling System
    • Radiator transition flange
  • Enclosures
    • Panel viewing window
    • External emergency stop
    • Sound attenuated enclosure, level 2
    • Weatherproof enclosure
    • Sound attenuated enclosure, level 1
  • Fuel System
    • 5 gallon fill containment
    • Tank riser
    • 209 and 394 gallon sub-base fuel tanks
    • Emergency vent pipe
    • 5 gallon spill containment
  • Mounting System
    • Seismic vibration isolators
  • Tests
    • Generator test report
    • PGS test report @ 0.8 power factor
    • 4 Hour factory test
    • PGS test report @ 1.0 power factor
  • Exhaust System
    • 10, 25 and 35 dBA silencer systems
    • Overhead silencer mounting kit
  • Generators
    • Permanent magnet generator