Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Maximum Rating 60 ekW
Minimum Rating 36 ekW
Emissions/Fuel Strategy U.S. EPA Cert., Tier 3
Voltage 208 to 600 Volts
Duty Cycle Standby, Prime
Emissions/Fuel Strategy U.S. EPA Cert., Tier 3
Frequency 60 Hz
Maximum Rating 60 ekW
Minimum Rating 36 ekW
Speed 1800 rpm
Voltage 208 to 600 Volts
Aspiration Turbocharged
Bore 4.13in
Compression Ratio 18.2:1
Displacement 268.5in
Engine Model C4.4, In-line 4, 4-cycle diesel
Fuel System Electronic (adjustable)
Governor Type Adem™A4
Stroke 5in
Height - Maximum 53.6in
Length - Maximum 75.8in
Width - Maximum 44.1in
IBC seismic and wind Certifications
NFPA battery charger UL10A 120VAC
Air cleaner
Cartridge type air filter
Second circuit breaker box
3-Pole 100% rated
Power terminal strip
Breakers (100% UL rated)
1000028996
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank
Coolant drain line with valve
Radiator and cooling fan with guards
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Radiator stone guard
12 Leads
Mechanical and electrical governing system - model dependent
Oil drain line with valve
Lubricating oil
WCA1 Low coolant temperature alarm
WSS1 Low coolant level shut down
FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
NFPA110 bundle includes:
PAA1 Panel mounted audible alarm
A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
Oil temperature gauge and sender
PBC10NU NFPA battery charger
Ground fault relay
Discrete I/O module
Volt free contacts genset run and common alarm
Audible alarm
Remote E-stop button
Remote annunciator module
Low coolant temperature alarm
Protective devices:
Overload shutdown via breaker
Fuel level reading
Low coolant level shutdown
Engine and alternator pre-paint, Caterpillar yellow
24V battery with rack and cables
Batteries
IBC seismic and wind Certifications
R Frame auxilliary winding
Cartridge type air filter
NFPA battery charger UL10A 120VAC
3-Pole 100% rated
Breakers (100% UL rated)
Second circuit breaker box
Power terminal strip
Discrete I/O module
Remote annunciator module
Remote E-stop button
Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
Ground fault relay
Audible alarm
Oil temperature gauge and sender
Volt free contacts genset run and common alarm
NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
Coolant heater
Battery heater
Anti-condensation heater
Lube oil sump heater
Jacket water heater
Wiring for canopy space heater
Radiator transition flange
Panel viewing window
External emergency stop
Sound attenuated enclosure, Level 2
Weatherproof enclosure
Sound attenuated enclosure, Level 1
5 Gallon fill containment
Tank riser
209 and 394 gallon sub-base fuel tanks
Emergency vent pipe
5 Gallon spill containment
Seismic vibration isolators
Generator test report
PGS Test report @ 0.8 power factor
4 Hour factory test
PGS Test report @ 1.0 power factor
10, 25 and 35 dBA silencer systems
Overhead silencer mounting kit
Permanent magnet excitation (PMG) generator