DE55 GC Generator Set (60 Hz)

DE55 GC Generator Set (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Frequency 60 Hz

  • Maximum Rating 50 ekW

  • Emissions/Fuel Strategy Non Regulated

  • Voltage 220 to 480 Volts

Request a quote

Product Specifications

Specifications

Generator Set Specifications

  • Duty Cycle Standby

  • Emissions/Fuel Strategy Non Regulated

  • Frequency 60 Hz

  • Maximum Rating 50 ekW

  • Minimum Rating 50 ekW

  • Speed 1800 rpm

  • Voltage 220 to 480 Volts

Engine Specifications

  • Aspiration Turbocharged

  • Bore 4.1in

  • Compression Ratio 17.25:1

  • Displacement 201.4in³

  • Engine Model Cat® C3.3, In-line 3, 4-cycle diesel

  • Fuel System Inline

  • Governor Type Mechanical

  • Stroke 5in

Generator Set Dimensions

  • Dry Weight - Genset (maximum) 2114lb

  • Height - Maximum 48.7in

  • Length - Maximum 76.6in

  • Width - Maximum 34.3in

Features

Equipment

Standard Equipment

  • C3.3, Inline 3 cylinder, 4 stroke diesel

  • GCCP 1.1

  • Mechanical governor

  • A Frame standard alternator

  • Single wall 8 hour fuel tank

  • Cat GC enclosure

  • Enclosure silencer

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Australia, CIS, Gulf Certification

  • Certificate of Conformance

  • Space heater

  • 120V

  • Dual wall 8 hour fuel tank

  • Low fuel level shutdown

  • Single wall tank with containment

  • Low fuel level alarm

  • High fuel level alarm

  • Battery charger

  • Volt free contacts for genset running

  • Volt free contacts for common alarm

  • Emergency stop with key

  • Earth leakage

  • USB to RS485 Communications device

  • Earth fault

  • Panel mounted audible alarm

  • Battery

  • Standby Pack (Smart Jacket water heater, Battery charger)

  • Coolant heater

  • Low coolant level shutdown

  • 3 Pole Circuit breaker 63A

  • 3 Pole Circuit breaker 80A

  • 3 Pole Circuit breaker 100A

  • 3 Pole Circuit breaker 125A

  • 3 Pole Circuit breaker 160A

  • 3 Pole Circuit breaker 200A

  • 4 Pole Circuit breaker 63A

  • 4 Pole Circuit breaker 80A

  • 4 Pole Circuit breaker 100A

  • 4 Pole Circuit breaker 125A

  • 4 Pole Circuit breaker 160A

  • 4 Pole Circuit breaker 200A

  • Circuit breaker padlock

  • Neutral earth link

  • Overload via alarm switch on breaker

  • PGS Test report @ 1.0 power factor

  • PGS Test report @ 0.8PF