3516C Generator Set

3516C Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Bore
6.69 in
Stroke (HD)
8.46 in
Aspiration
TA
Fuel System
Electronic unit injection

Engine Specifications

Bore
6.69in
Stroke (HD)
8.46in
Aspiration
TA
Fuel System
Electronic unit injection
Displacement
4764.73in
Engine Model
3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel
Stroke - Standard
7.48in
Compression Ratio
14.7:1
Governor Type
Adem™3
Aspiration
TA
Fuel System
Electronic unit injection
Bore
6.69in
Stroke - HD
8.46in
Stroke
7.48in

Generator Set Specifications

Duty Cycle
Standby, Mission Critical, Prime, Continuous
Minimum Rating
1650 ekW
Maximum Rating
2500 ekW
Voltage
380 to 13800 Volts
Frequency
60 Hz
Speed
1800 rpm
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 2

Generator Set Dimensions

Dry Weight - Genset (maximum)
38780lb
Height - Maximum
118.5in
Length - Maximum
295.1in
Width - Maximum
101.2in
Length - Minimum
284.6in
Width - Minimum
93.7in
Height - Minimum
116.5in
Dry Weight - Genset (minimum)
35880lb

Standard Equipment:

  • Air Inlet System
    • Air Cleaner; single element canister type
  • Air Inlet
    • Air Cleaner
  • Cooling
    • Package mounted radiator
  • Exhaust
    • Exhaust flange outlet
  • Control Panels
    • Number of I/O varies on options selected:
    • Engine cycle crank
    • Accessory module data link
    • Emergency stop pushbutton
    • Environmental sealed front face
    • Generator set packages include Caterpillar' s Voltage Regulator. IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
    • 6 Customer programmable digital inputs
    • Controls:
    • Serial annunciator module data link
    • Auto / start / stop control -
    • 1 Programmable digital outputs
    • Cat connect
    • Customer data link (Modbus RTU)
    • Reverse reactive power (kVAr) (32RV)
    • 24 Volt DC operation
    • Overcurrent (50 / 51)
    • Engine cool-down timer
    • Speed adjust -
    • Generator mounted - rear facing
    • 4 Programmable relay outputs (Form A)
    • 1 Programmable relay outputs (Form C)
    • EMCP 4.2B
    • Communications:
    • Text alarm / event descriptions
    • Alarm acknowledge
    • Lamp test
    • Load histogram feature
    • Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
    • PLC functionality
    • Digital indication for:
    • RPM
    • DC volts
    • Operating hours
    • Volts (L-L & L-N)
    • Oil pressure (psi, kPa or bar)
    • Frequency (Hz)
    • Coolant temperature
    • Amps (per phase & average)
    • kVA (per phase, average & percent)
    • kW (per phase, average & percent)
    • kVAr (per phase, average & percent
    • Power Factor (per phase & average)
    • kW-hr (total)
    • kVAr-hr (total)
    • Emergency stop
    • Low oil pressure
    • Failure to start (overcrank)
    • High coolant temperature
    • Overspeed
    • Warning / shutdown with common LED indication of shutdowns for:
    • Programmable protective relaying functions:
    • Low coolant temperature
    • Low coolant level -
    • Generator phase sequence
    • Reverse power (kW) (32)
    • Over / under voltage (27 / 59)
    • Over / under Frequency (81 o/u)
  • Fuel
    • Fuel priming pump
    • Primary fuel filter with integral water separator
    • Secondary fuel filter
  • Generator
    • Matched to the performance and output characteristics of Cat engines
    • IP23 Protection
  • Power Termination
    • Bus Bar
  • Control Panel
    • EMCP 4 Genset Controller
  • Cooling System
    • ATAAC - 3516E Package Radiators shipped installed
    • Certified standard PGS provided
  • Exhaust System
    • Dry exhaust manifold
    • Flanged faced outlet(s)
  • Fuel System
    • Flexible fuel lines - shipped loose
    • Secondary fuel filters
    • Fuel priming pump
    • Fuel cooler; not included with packages without radiator
  • General
    • Paint - Caterpillar Yellow except rails and radiators gloss black
    • Flywheel and flywheel housing - SAE No. 00
    • Caterpillar yellow with high gloss black rails and radiator
    • Right hand servicing
    • SAE Standard rotation
  • Generator And Attachments
    • Random wound
    • Permanent magnet
    • Medium Voltage:
    • Permanent magnet
    • Form wound
    • Winding temperature detectors
    • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
    • Bus bar connections, right side extension box, bottom cable entry
    • Form wound
    • 3 Phase brushless, salient pole
    • Low Voltage:
    • Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • Internal excitation
    • NEMA standard hole pattern
    • 6 lead
    • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • Winding temperature detectors
    • High Voltage:
    • Busbar connections, top center mounted, top cable entry
    • Winding temperature detectors
    • Anti condensation space heater
    • NEMA standard hole pattern
    • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Governing System
    • ADEM A3
  • Literature
    • English
  • Lubrication System
    • Oil drain lines and valve
    • Integral lube oil cool
    • Lubricating oil
    • Fumes disposal
    • Gear type lube oil pump
    • Oil filter, filler and dipstick
  • Mounting System
    • Anti-vibration mounts (shipped loose)
    • Rails - engine/generator/radiator mounting
    • Rubber anti-vibration mounts (shipped loose)
  • Starting System
    • 45 Amp charging alternator
    • Battery disconnect switch
    • Battery and battery rack w/cables
    • 24 Volt electric starting motor

Optional Equipment:

  • Control System
    • EMCP4.3, EMCP 4.4
  • Exhaust
    • Exhaust mufflers
  • Air Inlet System
    • Dual element air cleaner
    • Single element filter
  • Generator
    • Anti-condensation heater
    • Oversize and premium generators
    • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
  • Cooling System
    • Standard ambient ATAAC radiators
    • Optional installed radiators
    • Water level switch gauges
    • Optional installed ATAAC radiators
    • Standard ambient radiators
    • Coolant
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Crankcase System
    • Explosion relief valves
    • No explosion relief valves
    • Ventilation system
  • Control Panels
    • Digital I/O module
    • EMCP (4.2) (4.3) (4.4)
    • Load share module
    • Generator temperature monitoring & protection
    • Remote monitoring software
  • Exhaust System
    • Y-Adapters
    • Tier 4 clean emission MOD Kits
    • Flexible fittings
    • Tier 4 clean emissions module
    • Flanges
    • Clean emission parts
    • Exhaust offset
    • Tier 4 dosing cabinet
    • Flange and exhaust expanders
    • Elbows
    • Mufflers
  • Mounting
    • Rubber anti-vibration mounts
    • IBC isolators
    • Spring-type vibration isolator
  • Starting/charging
    • Charging alternator
    • Heavy-duty starting system
    • Air starting motor with control and silencer
    • Battery chargers
    • Jacket water heater
    • Oversize batteries
  • Fuel System
    • Primary Fuel Filter
    • Fuel Priming Pumps (Tier 4) - Manual or Electric
  • General
    • EU Certificate of Conformance (CE)
    • The following options are based on regional and product configuration:
    • Integral & sub-base UL listed dual wall fuel tanks
    • CSA Certification
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • UL 2200 package
    • EEC Declaration of Conformity
    • Integral & sub-base fuel tanks
    • Automatic transfer switches (ATS)
    • Enclosures: sound attenuated, weather protective
    • US aid emblem
    • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • Generators And Attachments
    • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
    • Alternator air cleaner
    • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
    • Differential current transformers (DCT)
    • Thermostate for space heater
    • Space heater kits
    • Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
    • Differntial current transformers (DCT) 8.7 kV and 15 kV classes
    • Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
    • Generator conversion
  • Instrumentation
    • Pyrometer and thermocouples
  • Lubrication System
    • Lube oil in standard sump
    • Prelube pumps
    • Oil level regulator
  • Mounting System
    • IBC vibration isolators
    • Puck style low efficiency isolators
    • Spring type vibration isolators
  • Power Connections
    • Ground cables between generator and terminal box
    • Neutral ground connections
    • Right side power connections
    • Left side power connections
    • Rear power connections
    • Low voltage circuit breakers
    • Center post busbar
    • 2700 Frame, four lead, four terminal
  • Special Tests / Reports
    • Torsional vibration analysis reports
    • Standard engine test charge
    • PGS test report @ 1.0 power factor
    • IBC certification
    • Canadian Standards Association certification
    • generator test report
    • OSHPD certification
    • Fuel consumption test
    • Generator set fuel consumption test
    • PGS test report @ 0.8 power factor
  • Starting And Charging
    • 24 Volt battery set - Dry
    • Electric starting motors
    • 10, 20, 35 and 50 amp battery chargers
    • Jacket water heaters
    • Air pressure regulator
    • Engine barring device
    • Starter cover
    • Air starting motors
  • Extended Service Coverage
    • Platinum, Gold and Silver coverage