3516 Diesel Generator Set

3516 Diesel Generator Set

The 3516 generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.

  • Standby Rating 1750 ekW

  • Prime Power Rating 1600 ekW

  • Emissions/Fuel Strategy Low Fuel, Low Emissions

  • Voltage 380 to 13800 Volts

Request a quote

Product Specifications

Specifications

Generator Set Specifications

  • Duty Cycle Standby, Mission Critical, Prime, Continuous

  • Emissions/Fuel Strategy Low Fuel, Low Emissions

  • Frequency 60 Hz

  • Maximum Rating 1750 ekW

  • Minimum Rating 1450 ekW

  • Prime Power Rating 1600 ekW

  • Speed 1800 rpm

  • Standby Rating 1750 ekW

  • Voltage 380 to 13800 Volts

Engine Specifications

  • Aspiration TA

  • Bore 6.69in

  • Compression Ratio 13.0:1

  • Displacement 4210.64in³

  • Engine Model 3516 TA, V-16, 4-Stroke Water-Cooled Diesel

  • Fuel System Mechanical unit injection

  • Governor Type Woodward

  • Stroke 7.48in

Generator Set Dimensions

  • Dry Weight - Genset (maximum) 28840lb

  • Height - Maximum 94.9in

  • Length - Maximum 247in

  • Width - Maximum 90in

Features

Equipment

Standard Equipment

  • Air cleaner; single element canister type

  • Accessory module data link

  • Low coolant level

  • Environmental sealed front face

  • EMCP 4.2B

  • 6 Customer programmable digital inputs

  • Communications:

  • Load histogram feature

  • Overspeed

  • Alarm acknowledge

  • kW-hr (total)

  • 24 Volt DC operation

  • Over/under voltage (27/59)

  • 1 programmable relay outputs (Form C)

  • kVAr-hr (total)

  • Emergency stop pushbutton

  • PLC functionality

  • Speed adjust

  • Lamp test

  • Auto/start/stop control

  • Over/under frequency (81 o/u)

  • Generator phase sequence

  • Revers Power (kW) (32)

  • Oil pressure (psi, kPa or bar

  • Coolant temperature

  • RPM

  • Overcurrent (50/51)

  • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor

  • Controls:

  • Number of I/O varies on options selected

  • Power factor (per phase & average)

  • 0 True RMS AC metering, 3-phase, +/-2% accuracy

  • kVA (per phase, average & percent)

  • Serial annunciator module data link

  • Customizable screens

  • Generator mounted - rear facing

  • kW (per phase, average & percent)

  • Text alarm/event descriptions

  • DC volts

  • Low oil pressure

  • Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy

  • Reverse reactive power (kVAr) (32RV

  • Frequency (Hz)

  • Low coolant temperature

  • 3 Analog inputs

  • Cat connect

  • kVAr (per phase, average & percent)

  • Warning/shutdown with common LED indication of shutdowns for:

  • Engine cycle crank

  • Failure to start (overcrank)

  • Programmable protective relaying functions:

  • Emergency stop

  • Customer data link (Modbus RTU

  • Engine cool-down timer

  • Volts (L-L & L-N)

  • Amps (per phase & average)

  • Operating hours

  • High coolant temperature

  • Digital indication for:

  • 1 programmable digital outputs

  • 4 programmable relay outputs (Form A)

  • Certified standard PGS provided

  • Flanged faced outlet(s)

  • Dry exhaust manifold

  • Secondary fuel filters

  • Fuel cooler; not included with packages without radiator

  • Flexible fuel lines - shipped loose

  • Fuel priming pump

  • Right hand servicing

  • Flywheel and flywheel housing - SAE No. 00

  • SAE standard rotation

  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)

  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)

  • Winding temperature detectors

  • Winding temperature detectors

  • Permanent magnet excitation (PMG)

  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)

  • Six lead

  • Permanent magnet excitation (PMG)

  • Internal excitation (IE)

  • 3 Phase brushless, Salient pole

  • Winding temperature detectors

  • Medium voltage:

  • Random wound

  • Anti-condensation space heater

  • Low voltage:

  • High voltage:

  • Busbar connections, top center mounted, top cable entry

  • Form wound

  • Busbar connections, right side extension box, bottom cable entry

  • Form wound

  • NEMA standard hole pattern

  • NEMA standard hole pattern

  • ADEM A3

  • Parts book

  • Fumes disposal

  • Lubricating oil

  • Gear type lube oil pump

  • Oil filter, filler and dipstick

  • Oil drain lines and valve

  • Integral lube oil cool

  • Rails - engine/generator/radiator mounting

  • Anti-vibration mounts (shipped loose)

  • Rubber anti-vibration mounts - shipped loose

  • Battery and battery rack w/cables

  • 45 Amp Charging alternator

  • Battery disconnect switch

  • 24 Volt electric starting motor

Optional Equipment

  • Controller: EMCP 4.2B

  • Local annunciator module: [ ] NFPA 110 [ ] Custom

  • Dual element air cleaner

  • Single element filter

  • Standard ambient radiators

  • Coolant

  • Optional installed ATAAC radiators

  • Optional installed radiators

  • Water level switch gauges

  • Standard ambient ATAAC radiators

  • Starting motors: [ ] Standard [ ] Heavy duty

  • Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)

  • Starting aids: [ ] 220V 50 Hz Jacket water heater

  • Battery charger: [ ] 10A [ ] 20A [ ] 35A

  • Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners

  • Muffler: [ ] Industrial Grade

  • No explosion relief valves

  • Ventilation system

  • Explosion relief valves

  • Temperature rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C

  • Y Adapters

  • Tier 4 clean emissions module

  • Tier 4 dosing cabinet

  • Elbows

  • Tier 4 clean emission MOD Kits

  • Exhaust offset

  • Flanges

  • Flange and exhaust expanders

  • Flexible fittings

  • Mufflers

  • Clean emission parts

  • Fuel priming pumps (Tier 4) - Manual or electric

  • Primary fuel filter

  • US aid emblem

  • Special paint (Colors other than Caterpillar yellow or high performance paints)

  • The following options are based on regional and product configuration:

  • UL 2200 package

  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

  • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

  • Generator conversion

  • Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

  • Thermostat for space heater

  • Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame

  • Alternator air cleaner

  • Differential current transformers (DCT)

  • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

  • Differential current transformers (DCT) 8.7 kV and 15 kV classes

  • Space heater kit

  • Circuit breaker operation: [ ] Electrical

  • Circuit breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A

  • Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P

  • Power termination: [ ] Busbar [ ] Circuit breaker

  • Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year

  • Pyrometer and Thermocouples

  • Lube oil in standard sump

  • Prelube pumps

  • Oil level regulator

  • Puck style low efficiency isolators

  • Spring type vibration isolators

  • IBC vibration isolators

  • Ground cables between generator and terminal box

  • Neutral ground connections

  • 2700 Frame, four lead, four terminal

  • Rear power connections

  • Right side power connections

  • Left side power connections

  • Low voltage Circuit breakers

  • Center post busbars

  • Generator test report

  • OSHPD Certification

  • Canadian Standards Association certification

  • PGS Test report @ 1.0 power factor

  • IBC Certification

  • Fuel consumption test

  • Generator set fuel consumption test

  • PGS Test report @ 0.8 power factor

  • Standard engine test charge

  • Torsional vibration analysis reports

  • Electric starting motors

  • Air pressure regulator

  • Starter cover

  • Air starting motors

  • 24 Volt battery set - Dry

  • 10, 20, 35 and 50 Amp Battery chargers

  • Jacket water heaters

  • Engine barring device

  • Platinum, Gold and Silver coverage