C2.2 Generator Set

C2.2 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Maximum Rating 22.0 kVA

  • Minimum Rating 13.0 kVA

  • Emissions/Fuel Strategy R96/EUIIIa Equivalent

  • Voltage 110 to 415 Volts

Request a quote

Product Specifications

Specifications

Generator Set Specifications

  • Duty Cycle Standby, Prime

  • Emissions/Fuel Strategy R96/EUIIIa Equivalent

  • Frequency 50 Hz

  • Maximum Rating 22.0 kVA

  • Minimum Rating 13.0 kVA

  • Speed 1500 rpm

  • Voltage 110 to 415 Volts

Engine Specifications

  • Aspiration Naturally Aspirated

  • Bore 3.3in

  • Compression Ratio 22.5:1

  • Displacement 135.2in³

  • Engine Model Cat® C2.2, In-line 4, 4-cycle diesel

  • Fuel System Indirect Injection

  • Governor Type Mechanical

  • Stroke 3.9in

Generator Set Dimensions

  • Height - Maximum 43.9in

  • Length - Maximum 59.1in

  • Width - Maximum 24.4in

Features

Equipment

Standard Equipment

  • GCCP 1.3

  • Air cleaner; light duty with disposable element

  • Radiator and cooling fan with guards

  • Caterpillar extended life coolant

  • Coolant drain line with valve

  • Fan drive, battery charging alternator drive

  • Standard open set fuel tank/base supplied

  • Base, formed steel with single wall integral 8-hour fuel tank

  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose

  • Voltage regulator (single phase sensing)

  • Segregated low voltage (AC/DC) wiring panel

  • Tower panel, IP22, bottom cable entry

  • IP23 Protection

  • Circuit breaker, IEC, 3 pole, mounted in tower panel

  • 12 Leads

  • Mechanical governing system

  • Oil drain line with valve

  • Lubricating oil

  • Captive linear vibration isolators between base and engine-generator

  • includes lifting provisions and termination points for coolant

  • 12 Volt battery with rack and cables

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Coastal insulation protection

  • European upgrade to STD set for CE certificate

  • Global certification for CIS

  • Padlockable breaker device

  • 4 Pole Circuit breaker

  • Emergency stop with key

  • Volt free contacts for common alarm

  • Volt free contacts for genset running

  • GCCP 1.3

  • Battery charger

  • Coolant heater

  • Sound attenuated enclosure (GALV)

  • Single point lift for enclosure

  • Low fuel level alarm

  • Industrial silencer removal

  • Silencer installation kit

  • Battery removal

  • PGS Test report @ 1.0 power factor

  • Packing case - compact set

  • Packing case - canopied set

  • Radiator stone guard