Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Maximum Rating 50 ekW
Minimum Rating 50 ekW
Emissions/Fuel Strategy U.S. EPA Cert., Tier 3, SCAQMD Compliant
Voltage 208 to 600 Volts
Duty Cycle Standby
Emissions/Fuel Strategy U.S. EPA Cert., Tier 3, SCAQMD Compliant
Frequency 60 Hz
Maximum Rating 50 ekW
Minimum Rating 50 ekW
Speed 1800 rpm
Voltage 208 to 600 Volts
Aspiration Turbocharged
Bore 4.1in
Compression Ratio 18.2:1
Displacement 269in
Engine Model C4.4, In-line 4, 4-cycle diesel
Fuel System Common Rail
Governor Type Mechanical, ADEM™A4
Stroke 5in
Dry Weight - Genset (maximum) 2055lb
Height - Maximum 48in
Length - Maximum 77.2in
Width - Maximum 43.3in
IBC seismic and wind Certifications
Air cleaner
Cartridge type air filter
Second circuit breaker box
Power terminal strip
Breakers (100% UL rated)
3-Pole 100% rated
NFPA battery charger UL10A 120VAC
GCCP 1.2 Control panel
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Radiator and cooling fan with guards
Coolant drain line with valve
Radiator stone guard
NFPA110 bundle includes:
WCA1 Low coolant temperature alarm
FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
WSS1 Low coolant level shut down
PBC10NU NFPA battery charger
Oil temperature gauge and sender
PAA1 Panel mounted audible alarm
A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
Audible alarm
Remote E-stop button
Ground fault relay
Discrete I/O module
Remote annunciator module
Volt free contacts genset run and common alarm
Fuel level reading
Protective devices:
Low coolant temperature alarm
Low coolant level shutdown
Overload shutdown via breaker
12 Leads
Mechanical and electrical governing system - model dependent
Lubricating oil
Oil drain line with valve
Engine and alternator pre-paint, Caterpillar yellow
Batteries
24V battery with rack and cables
IBC seismic and wind Certifications
Cartridge type air filter
R Frame auxilliary winding
NFPA battery charger UL10A 120VAC
Breakers (100% UL rated)
Power terminal strip
3-Pole 100% rated
Second circuit breaker box
Volt free contacts genset run and common alarm
Oil temperature gauge and sender
Remote E-stop button
Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
Audible alarm
Remote annunciator module
Discrete I/O module
NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
Ground fault relay
Radiator transition flange
External emergency stop
Sound attenuated enclosure, Level 2
Panel viewing window
10, 25 and 35 dBA silencer systems
Overhead silencer mounting kit
5 Gallon spill containment
209 and 394 gallon sub-base fuel tanks
Tank riser
Emergency vent pipe
5 Gallon fill containment
Coolant heater
Wiring for canopy space heater
Battery heater
Lube oil sump heater
Anti-condensation heater
Wiring for canopy space heater
Jacket water heater
Permanent magnet excitation (PMG) generator
Permanent magnet excitation (PMG) generator
Seismic vibration isolators
4 Hour factory test
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
Generator test report