Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Standby Rating 1500/1400 ekW
Prime Power Rating 1360/1275 ekW
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 13800 Volts
Duty Cycle Standby, Mission Critical, Prime, Continuous
Emissions/Fuel Strategy Low Fuel, Low Emissions
Frequency 60 Hz
Maximum Rating 1500 ekW
Minimum Rating 1230 ekW
Prime Power Rating 1360/1275 ekW
Speed 1800 rpm
Standby Rating 1500/1400 ekW
Voltage 380 to 13800 Volts
Aspiration TA
Bore 6.69in
Compression Ratio 14.0:1 Std 15.5:1 HD
Displacement 3573.55in³
Engine Model 3512B TA, V-12, 4-Stroke Water-Cooled Diesel
Fuel System Electronic Unit Injection
Governor Type ADEM™ A3
Stroke 7.48in
Dry Weight - Genset (maximum) 25090lb
Dry Weight - Genset (minimum) 24430lb
Height - Maximum 93.2in
Length - Maximum 221.9in
Width - Maximum 90in
Air cleaner; single element canister type with service indicator
Exhaust flange outlet
Dry exhaust manifold
Flanged faced outlet(s)
IP23 Protection
Matched to the performance and output characteristics of Cat engines
Busbar
Cat ECS Genset controller
Alarm acknowledge
kW-hr (total)
Lamp test
Over/under voltage (27 / 59)
Digital indication for:
DC volts
PLC functionality
Speed adjust
4 Programmable relay outputs (Form A)?
Text alarm/event descriptions
Warning/shutdown with common LED indication of shutdowns for:
Engine cycle crank
Emergency stop
Auto/start/stop control
RPM
Reverse power (kW) (32)
True RMS AC metering, 3-phase, +/-2% accuracy
Accessory module data link
Low coolant level
kVAr-hr (total)
kVAr (per phase, average & percent)
1 Programmable relay outputs (Form C)
Over/under frequency (81 o/u)
Low oil pressure
Amps (per phase & average)
Failure to start (overcrank)
Cat ECS 100
Controls:
High coolant temperature
Communications
Number of I/O varies on options selected
24 Volt DC operation
Engine cool-down timer
Low coolant temperature
Generator phase sequence
Frequency (Hz)
Volts (L-L & L-N)
Reverse reactive power (kVAr) (32RV)
Oil pressure (psi, kPa or bar)
Customizable screens
Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min max exciter. Limiter and exciter diode monitor
Load histogram feature
1 Programmable digital outputs
Customer data link (Modbus RTU)
Overspeed
Environmental sealed front face
Coolant temperature
kW (per phase, average & percent)
Programmable protective relaying functions:
kVA (per phase, average & percent)
Power factor (per phase & average)
Emergency stop pushbutton
Generator mounted - rear facing
Cat connect
Overcurrent (50 / 51)
Package mounted radiator
Radiator fan and fan drive
Fan and belt guards
Coolant drain line with valve
Caterpillar extended life coolant (Not included with packages without radiator, installed SF44CTS
Coolant level sensors (Not included with packages without radiator)
SCAC
Primary fuel filter with integral water separator
Secondary fuel filters
Flexible fuel lines - shipped loose
Fuel priming pump
Fuel cooler; not included with packages without radiator
Low voltage:
Random wound
6 Leads
NEMA standard hole pattern
High voltage
Busbar connections, right side extension box, bottom cable entry
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
Permanent magnet excitation (PMG)
NEMA standard hole pattern
Medium voltage:
Busbar connections, top center mounted, top cable entry
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
Winding temperature detectors
Form wound
3 Phase brushless, Salient pole
Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
Internal excitation (IE)
ADEM III
Parts book
Lubricating oil
Gear type lube oil pump
Oil drain lines and valve
Fumes disposal
Integral lube Oil cooler
Oil filter, filler and dipstick
Rubber anti-vibration mounts - shipped loose
Battery disconnect switch
Battery and battery rack w/cables
45 Amp Charging alternator
24 Volt electric starting motor
Paint - Caterpillar yellow with high gloss black rails & radiator
Flywheel and Flywheel housing-SAE No. 00
Right hand servicing
SAE standard rotation
Remote monitoring software
Digital I/O module
EMCP 4.4
Load share module
Generator temperature monitoring & protection
Exhaust mufflers
Flanges
Elbows
Flange and exhaust expanders
Mufflers
Y Adapters
Flexible fittings
Oversize and premium generators
Permanent magnet excitation (PMG)
Internal excitation (IE)
Anti-condensation heater
Heavy duty air cleaner
Single element filter
Circuit breakers, UL listed
Circuit breakers, IEC compliant
Standard installed radiators
Optional installed radicators
Coolant
Water level switch gauges
Primary fuel filter
UL 2200 package
EEC Declaration of Conformity
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
CSA Certification
Enclosures: Sound attenuated, weather protective
Automatic transfer switches (ATS)
Integral & sub-base fuel tanks
The following options are based on regional and product configuration:
US aid emblem
Integral & sub-base UL listed dual wall fuel tanks
EU Certificate of Conformance (CE)
1400, 1600, 2700 Frames
Generator conversion from IE to PM
Space heater
RW, IE, 6 Leads, Pitch 0.6667
Low voltage: 380,440 / 480 Volts, 3 Phase, 1800 rpm
Differential current transformers (DCT) 15 kV class
Generator air cleaner
Differential current transformers (DCT) 8.7 kV class
IBC isolators
Rubber anti-vibration mounts
Spring type vibration isolators
Air starting motor with control and silencer
Heavy duty starting system
Charging alternator
Oversize batteries
Battery chargers
Jacket water heater
Wiring GP W/O cyl sensors
Pyrometer and thermocouples
Lubrication oil in standard sump
Oil drains
Prelube pumps
Oil level regulator
Explosion relief valves
No crankcase explosion relief valves
Crankcase ventilation system
No explosion relief valves
IBC vibration isolators
Puck style low efficiency isolators
Spring type vibration isolators
2000, 2500 Amp, 4 Pole, IECrated Circuit breakers
Cable entry - right side
Grounding groups
Left side power connections
1600 ,2000, 2500, 3000, 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers
Rear power connections
Neutral ground connections
6 Leads, 6 terminal option
Right side power connections
Center post buss bar
Generator test report
PGS Test report @ 0.8 power factor
Standard engine test charge
CSA Certification
Torsional vibration analysis
Generator fuel consumption test
PGS Test report @ 1.0 power factor
IBC seismic Certification
Fuel consumption test
Air pressure regulator
Batteries, racks and cables:
Air starting motor
35 Amp Battery charger
24 Volt battery set - Dry
Starter cover
10 Amp Battery charger
Engine barring device
Jacket water heaters
Electric starting motors