Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Standby Rating 2500/2250/2000 ekW
Prime Power Rating 2250/2045/1825 ekW
Emissions/Fuel Strategy U.S. EPA Cert., Tier 2
Voltage 380 to 13800 Volts
Duty Cycle Standby, Mission Critical, Prime, Continuous
Emissions/Fuel Strategy U.S. EPA Cert., Tier 2
Frequency 60 Hz
Maximum Rating 2500 ekW
Minimum Rating 1650 ekW
Prime Power Rating 2250/2045/1825 ekW
Speed 1800 rpm
Standby Rating 2500/2250/2000 ekW
Voltage 380 to 13800 Volts
Aspiration TA
Bore 6.69in
Compression Ratio 14.7:1
Displacement 4764.73in
Engine Model 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel
Fuel System Electronic unit injection
Governor Type Adem™3
Stroke 7.48in
Stroke - HD 8.46in
Dry Weight - Genset (maximum) 38780lb
Dry Weight - Genset (minimum) 35880lb
Height - Maximum 118.5in
Height - Minimum 116.5in
Length - Maximum 295.1in
Length - Minimum 284.6in
Width - Maximum 101.2in
Width - Minimum 93.7in
Air cleaner; single element canister type
Package mounted radiator
Exhaust flange outlet
Communications:
Reverse reactive power (kVAr) (32RV)
Customer data link (Modbus RTU)
Generator mounted - rear facing
1 Programmable digital outputs
Auto/start/stop control -
Serial annunciator module data link
Engine cool-down timer
24 Volt DC operation
Controls:
Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
Alarm acknowledge
Cat connect
Engine cycle crank
Text alarm/event descriptions
Overcurrent (50 / 51)
Accessory module data link
Cat ECS 100
1 Programmable relay outputs (Form C)
Emergency stop pushbutton
Speed adjust
4 Programmable relay outputs (Form A)
Number of I/O varies on options selected
6 Customer programmable digital inputs
Environmental sealed front face
Load histogram feature
Lamp test
PLC functionality
Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
Digital indication for:
Operating hours
RPM
DC volts
Frequency (Hz)
Coolant temperature
Volts (L-L & L-N)
Oil pressure (psi, kPa or bar)
Amps (per phase & average)
kVAr (per phase, average & percent)
kVA (per phase, average & percent)
kW (per phase, average & percent)
Power factor (per phase & average)
kW-hr (total)
kVAr-hr (total)
High coolant temperature
Overspeed
Failure to start (overcrank)
Warning/shutdown with common LED indication of shutdowns for:
Emergency stop
Low oil pressure
Low coolant level
Low coolant temperature
Programmable protective relaying functions:
Over/under frequency (81 o/u)
Generator phase sequence
Over/under voltage (27 / 59)
Reverse power (kW) (32)
Primary fuel filter with integral water separator
Matched to the performance and output characteristics of Cat engines
IP23 Protection
Busbar
Cat ECS Genset controller
Certified standard PGS provided
Flanged faced outlet(s)
Dry exhaust manifold
Flexible fuel lines - shipped loose
Fuel cooler; not included with packages without radiator
Secondary fuel filters
Fuel priming pump
Caterpillar yellow with high gloss black rails and radiator
Right hand servicing
Flywheel and flywheel housing - SAE No. 00
Paint - Caterpillar yellow except rails and radiators gloss black
SAE standard rotation
Busbar connections, top center mounted, top cable entry
Class H temperature rise at 40C ambient (125C prime / 150C standby)
Low voltage:
NEMA standard hole pattern
Medium voltage:
Anti-condensation space heater
6 Lead
Random wound
Form wound
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
Permanent magnet excitation (PMG)
Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
Internal excitation (IE)
3 Phase brushless, Salient pole
High voltage:
Winding temperature detectors
Busbar connections, right side extension box, bottom cable entry
ADEM A3
Parts book
Lubricating oil
Fumes disposal
Integral lube oil cool
Oil drain lines and valve
Oil filter, filler and dipstick
Gear type lube oil pump
Anti-vibration mounts (shipped loose)
Rubber anti-vibration mounts - shipped loose
Rails - engine/generator/radiator mounting
Battery disconnect switch
45 Amp Charging alternator
24 Volt electric starting motor
Battery and battery rack w/cables
EMCP 4.4
Exhaust mufflers
Single element filter
Dual element air cleaner
Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
Oversize and premium generators
Anti-condensation heater
Coolant
Standard ambient ATAAC radiators
Optional installed radiators
Optional installed ATAAC radiators
Standard ambient radiators
Water level switch gauges
Circuit breakers, UL listed
Circuit breakers, IEC compliant
Explosion relief valves
Ventilation system
No explosion relief valves
Load share module
Digital I/O module
Generator temperature monitoring & protection
Remote monitoring software
Rubber anti-vibration mounts
IBC isolators
Y Adapters
Flexible fittings
Exhaust offset
Tier 4 clean emissions module
Elbows
Flange and exhaust expanders
Tier 4 clean emission MOD Kits
Tier 4 dosing cabinet
Flanges
Mufflers
Clean emission parts
Oversize batteries
Battery chargers
Charging alternator
Air starting motor with control and silencer
Heavy duty starting system
Primary fuel filter
The following options are based on regional and product configuration:
UL 2200 package
CSA Certification
EEC Declaration of Conformity
Special paint (Colors other than Caterpillar yellow or high performance paints)
Integral & sub-base fuel tanks
US aid emblem
Enclosures: Sound attenuated, weather protective
Automatic transfer switches (ATS)
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
EU Certificate of Conformance (CE)
Integral & sub-base UL listed dual wall fuel tanks
High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
Thermostat for space heater
Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
Differential current transformers (DCT) 8.7 kV and 15 kV classes
Generator conversion
Space heater kit
Alternator air cleaner
Pyrometer and thermocouples
Oil level regulator
Lube oil in standard sump
Prelube pumps
Puck style low efficiency isolators
Spring type vibration isolators
IBC vibration isolators
Ground cables between generator and terminal box
Neutral ground connections
Left side power connections
Center post busbars
Right side power connections
2700 Frame, four lead, four terminal
Rear power connections
Low voltage Circuit breakers
IBC Certification
Fuel consumption test
Generator test report
PGS Test report @ 1.0 power factor
Torsional vibration analysis reports
OSHPD Certification
Generator set fuel consumption test
PGS Test report @ 0.8 power factor
Standard engine test charge
Canadian Standards Association certification
Air pressure regulator
Starter cover
Air starting motors
10, 20, 35 and 50 Amp Battery chargers
Electric starting motors
Jacket water heaters
24 Volt battery set - Dry
Engine barring device
Platinum, Gold and Silver coverage