D200 GC Generator Set

D200 GC Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Standby Rating 200 ekW

  • Frequency 60 Hz

  • Emissions/Fuel Strategy U.S. EPA Tier 3 Certified

  • Voltage 208 to 600 Volts

Request a quote

Product Specifications

Specifications

Generator Set Specifications

  • Duty Cycle Standby

  • Emissions/Fuel Strategy U.S. EPA Tier 3 Certified

  • Frequency 60 Hz

  • Speed 1800 rpm

  • Standby Rating 200 ekW

  • Voltage 208 to 600 Volts

Engine Specifications

  • Aspiration Turbocharged, Air to Air Aftercooled

  • Bore 4.1in

  • Compression Ratio 16.7:1

  • Displacement 428in³

  • Engine Model C7.1 I-6, 4-Cycle Diesel

  • Fuel System Electronic, Common Rail

  • Governor Type ADEM™A4

  • Stroke 5.31in

Generator Set Dimensions

  • Dry Weight - Genset (maximum) 3917lb

  • Height - Maximum 58.7in

  • Length - Maximum 103.7in

  • Width - Maximum 51.2in

Features

Equipment

Standard Equipment

  • Air cleaner; light duty with disposable element

  • GCCP 1.2

  • Coolant drain line with valves

  • Radiator and cooling fan with guards

  • Caterpillar extended life coolant

  • Fan drive, battery charging alternator drive

  • Standard open set fuel tank wide base

  • Oil drain line with valve

  • Lubricating oil

  • Captive linear vibration isolators

  • Includes lifting provision and drag points

  • Termination points for coolant and lube oil drain lines

  • 24V battery with rack and cables

  • Cat electronic governor ADEM A4

  • Engine and alternator pre-paint, Caterpillar yellow

  • Cat® Product Link™ PL444 cellular

Optional Equipment

  • Battery disconnect switch

  • SE, AREP, PMG Excitation

  • Anti-condensation heater

  • Mounting & Duct plate

  • Single / Multi manual circuit breakers

  • 10,25,35 dBA mufflers / Enclosure muffler

  • Panel mounted audible alarm

  • NFPA 110 bundle

  • Emergency stop with key

  • Earth fault (2 wire only)

  • I/O Expansion module

  • Current transformer

  • Volt free contacts for common alarm

  • Static battery charger

  • Low coolant temperature

  • Jacket water heater

  • Low coolant level shutdown

  • Sound attenuated level 2 enclosure

  • 24 hrs integral fuel tank

  • Low fuel level alarm

  • Fuel vent pipe / Vent pipe extention

  • High fuel level alarm

  • Stone guards/radiator trans flange

  • IBC Seismic, UL2200

  • Circuit breaker, Neutral bars, Shunt trips