Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Maximum Rating 400 ekW
Minimum Rating 400 ekW
Emissions/Fuel Strategy EPA Stationary Emergency
Voltage 480 to 600 Volts
Duty Cycle Standby
Emissions/Fuel Strategy EPA Stationary Emergency
Frequency 60 Hz
Maximum Rating 400 ekW
Minimum Rating 400 ekW
Speed 1800 rpm
Voltage 480 to 600 Volts
Aspiration Turbocharged Air-to-Air Aftercooled
Bore 5.1in
Compression Ratio 16.3:1
Displacement 763in³
Engine Model Cat® C13 In-line 6, 4-cycle diesel
Fuel System MEUI
Governor Type ADEM™A4
Stroke 6.2in
Dry Weight - Genset (maximum) 4107lb
Dry Weight - Genset (minimum) 7330.4lb
Height - Maximum 96.7in
Height - Minimum 80.3in
Length - Maximum 182.8in
Width - Maximum 64.2in
Air cleaner - Non canister, disposable
Aftercooler core
Turbocharger
GCCP 1.2
Blower fan and fan drive with guards
Coolant drain valve
Radiator sight gauge
Radiator, package mounted
Jacket water pump, gear driven, centrifugal
Thermostats and housing
Exhaust manifold - dry
Primary fuel filter w/integral water separator and secondary filter, spin on
Engine fuel transfer pump
Fuel cooler
Fuel priming pump
Integral tank base, 24 hours, UL142
All protective devices and control functions simulated and checked
Complete system designed & built at ISO 9001:2000 certified facilities
Factory tested to design specifications at full load conditions
Insulation system, Class H
IP23 Protection
Standard winding protection for non-harsh environments with relative humidity ? 95%
6 Leads
Terminal box, IP22 RHS facing, bottom cable entry
Easy access to AVR and terminals
Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
Voltage regulator (single phase sensing)
Cat electronic governor (ADEM A4)
Fumes disposal to front of radiator
Lubricating oil, CK-4 (10W-30)
Oil cooler
Shallow oil pan
Oil filler and dipstick
Oil filter, spin on
Oil drain with valve
Captive linear vibration isolators between base and engine-generator
Includes lifting provisions and termination points for coolant and lube oil drain lines
Safety shutoff - Low oil pressure
Safety shutoff - High water temperature
Safety shutoff - Overspeed
24-volt electric starting motor
24V, 45 Amp Charging alternator
Lifting eyes
Vibration damper
Parts book
Air cleaner (Non canister disposable)
Audio & visual fuel alarm (@90% fuel level)
Integral tank base, 24 hours, UL142
5 Gallon Spill Containment
Fuel tank pill pipe & lockable cap
Overfill prevention valve
Wide Base - Skid
1200A LSI
1200A LS/I
600A LS/I
400A LS/I
800A LS/I
600A LSI
Auxiliary contacts
800A LSI
400A LSI
Twist release, Red button emergency stop
Ground fault relay
Volt free contacts
Audible alarm Gp
16 -light NFPA 99/110 Annunciator
20A GFCI (Ground Fault Circuit Interrupter)
100A Load center
Product link remote monitoring hardware
AC & DC Source lights
E-Stop
Sound attenuated Level 2 enclosure (White)
8" Muffler - 25 dBA attenuation
Manifold and turbocharger guards
Flexible exhaust connection
Space heater
Permanent magnet excitation (PMG) generator
4 Pole (IEC-100% rated) Circuit breaker - Motorised
Circuit breaker (IEC) Auxiliary contacts
Shunt trip for IEC circuit breaker
Oversize battery set, 1400 CCA, 200 amp/hr
Standard battery set: 1000 CCA, 90 amp/hr.
Jacket water heater
Battery charger (UL Certified)
Generator test report
Extended Service Coverage
UL2200 Certification
CSA Certification
Jacket water heater
Battery disconnect switch