XQ2280 Tier 4 Final

XQ2280 Tier 4 Final

The Cat® XQ2280 rental power module meets U.S. EPA Tier 4 Final emission standards.

  • Rating Prime 1825 ekW (2280 kVA)

  • Frequency 60 Hz

  • Voltage 480/277 V

  • Fuel/Emissions Strategy U.S. EPA Tier 4 Final

Request a quote

Product Specifications

Specifications

Generator Set

  • Frequency 60 Hz

  • Fuel/Emissions Strategy U.S. EPA Tier 4 Final

  • Rating Prime 1825 ekW (2280 kVA)

  • Rating Standby 2000 ekW (2500 kVA)

  • Voltage 480/277 V

Engine

  • Engine Cat® 3516C

  • Fuel Diesel

Dimensions

  • Height - Without Chassis 2896mm

  • Length - Without Chassis 576in

  • Weight - Without Chassis, With Lube Oil and Coolant 82000lb

  • Width - Without Chassis 96in

Features

Equipment

Standard Equipment

  • Reliable, rugged, durable design

  • Electronic ADEM A4 engine control

  • EPA Tier 4 Final and CARB Emissions Certified

  • Turbocharged, air to water aftercooled

  • Aftertreatment module.
    DEF System

  • 3 Phase, brushless, 12 lead, Permanent Magnet Excited

  • 1667 Frame

  • Coastal insulation protection and anti-condensation space heaters

  • Integrated voltage regulator (IVR) with VAR/PF control

  • Sized for 120°C temperature rise at 40°C ambient

  • EMCP 4.4 Genset mounted digital controller

  • Externally accessible Color Touch-Screen HMI Control Center

  • Manual and automatic paralleling capability

  • Electrical governing system ADEM A3

  • Provides package monitoring and management

  • Horizontally, isolation-mounted radiator withvertical air discharge from the container

  • Provides 43°C ambient capability at Prime ratingand 500m

  • 120V, 50 Amp battery charger

  • 60 Amp charging alternator

  • Solar maintainer for batteries

  • Dual 24V Electric Starting Motors

  • 1050-gal (3975 L) double-wall fuel tank, UL 142and ULc 601 Listed and complies with Transport Canada requirements, 10-hour runtime @ 75%prime, external fuel fill

  • Transfer pump to on-board and off-board fuel

  • Primary fuel filters (3x) with integral water separator

  • External connections for fuel transfer and fuel tank overflow

  • Externally accessible, Vibration Isolated, 3200A LSIG, UL Listed, 100 kAIC breaker withadvanced protections and power metering

  • Busbar connections

  • Removable plexiglass plate w/safety switch for livebus protection

  • 48' ISO high cube container

  • Sound level is 81 dB(A) at 7 meters per SAEJ1074 measured at 75% prime load

  • Sound attenuated air intake louvers and five lockable personnel doors with panic release

  • Full flow oil filters with water-cooled oil cooler

  • Oil drain lines routed to the engine rail

  • Factory tested and inspected

  • Full manufacturer's warranty

  • UL, NEMA, ISO, and IEEE standards

Optional Equipment