DG230-2 (3 phase)

DG230-2 (3 phase)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Frequency 60 Hz

  • Natural Gas Rating 230 eKW

  • Emissions/Fuel Strategy U.S. EPA Certified for Non-Emergency Application

  • Speed 1800 rpm

Request a quote

Product Specifications

Specifications

Generator Set Specifications

  • Emissions/Fuel Strategy U.S. EPA Certified for Non-Emergency Application

  • Frequency 60 Hz

  • Natural Gas Rating 230 eKW

  • Speed 1800 rpm

Engine Specifications

  • Aspiration Turbocharged - Aftercooled

  • Bore 1463.1mm

  • Governor Type Electronic

  • Stroke 1728.3mm

Generator Set Dimensions

  • Height 68.04in

  • Length 2887kg

  • Weight 6364lb

  • Width 57.6in

Features

Equipment

Standard Equipment

  • Factory-installed radiator

  • Closed coolant recovery system

  • 50/50 Ethylene glycol antifreeze

  • Radiator and cooling fan complete with protective guards

  • Standard ambient temperatures up to 50°C (122°F)

  • Single element air filter

  • Low fuel pressure switch

  • Primary and secondary fuel shut-off

  • Fuel pressure test po

  • Dual lock off valves

  • Natural Gas or LP Vapor

  • NPT connection

  • Class H insulation material

  • Full load capacity alternator

  • Permanent magnet excitation

  • Class H insulation material

  • Full load capacity alternator

  • Integrated Voltage Regulator

  • Matched to the performance and output characteristics of Cat engines

  • Permanent magnet excitation

  • IP23 Protection

  • Exhaust outlet with 3” pipe

  • EMCP 4.2 Series generator set controller

  • Vibration isolaton (puck type)

  • Rubber vibration isolators

  • Battery charging alternator

  • Battery cables

  • Engine electrical system

  • Solenoid activated starter motor

  • Solenoid activated starter motor

  • Electronic governor (non adjustable)

  • EMCP 4.2 Series generator set controller

  • Batteries with rack and cables

  • 12 volt starting motor

Optional Equipment

  • Battery heater

  • Charging alternator

  • Jacket water heater

  • Battery charger – UL Listed 10 amp

  • Suitable for Use as Service Equipment (SUSE)

  • Automatic transfer switches (ATS)

  • CSA Certification

  • Enclosures: sound attenuated, weather protective

  • UL 2200 package

  • Anti-condensation heater

  • Shunt trip and auxiliary contact breaker

  • Thermal magnetic or electronic trip MCCBs

  • Excitation: [ ] Permanent Magnet Excited (PM)

  • Anti-condensation heater

  • Oversize and premium generators