Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Maximum Rating 40 ekW
Minimum Rating 40 ekW
Emissions/Fuel Strategy U.S. EPA Cert., Tier 3, SCAQMD Compliant
Voltage 208 to 600 Volts
Duty Cycle Standby
Emissions/Fuel Strategy U.S. EPA Cert., Tier 3, SCAQMD Compliant
Frequency 60 Hz
Maximum Rating 40 ekW
Minimum Rating 40 ekW
Speed 1800 rpm
Voltage 208 to 600 Volts
Aspiration Turbocharged
Bore 4.1in
Compression Ratio 18.2:1
Displacement 269in
Engine Model C4.4, In-line 4, 4-cycle diesel
Fuel System Common Rail
Governor Type Mechanical, ADEM™A4
Stroke 5in
Dry Weight - Genset (maximum) 1847lb
Height - Maximum 48in
Length - Maximum 77.2in
Width - Maximum 43.3in
IBC seismic and wind Certifications
Air cleaner
Cartridge type air filter
Breakers (100% UL rated)
Second circuit breaker box
3-Pole 100% rated
Power terminal strip
NFPA battery charger UL10A 120VAC
GCCP 1.2 Control panel
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
NFPA110 bundle includes:
WSS1 Low coolant level shut down
WCA1 Low coolant temperature alarm
FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
PBC10NU NFPA battery charger
Oil temperature gauge and sender
A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
PAA1 Panel mounted audible alarm
Remote E-stop button
Volt free contacts genset run and common alarm
Discrete I/O module
Audible alarm
Ground fault relay
Remote annunciator module
Overload shutdown via breaker
Low coolant level shutdown
Fuel level reading
Protective devices:
Low coolant temperature alarm
Caterpillar extended life coolant
Radiator and cooling fan with guards
Coolant drain line with valve
Fan drive, battery charging alternator drive
Radiator stone guard
12 Leads
Mechanical and electrical governing system - model dependent
Lubricating oil
Oil drain line with valve
Engine and alternator pre-paint, Caterpillar yellow
Batteries
24V battery with rack and cables
IBC seismic and wind Certifications
Cartridge type air filter
R Frame auxilliary winding
NFPA battery charger UL10A 120VAC
Power terminal strip
Second circuit breaker box
Breakers (100% UL rated)
3-Pole 100% rated
Volt free contacts genset run and common alarm
Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
Discrete I/O module
Audible alarm
Ground fault relay
Remote annunciator module
NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
Oil temperature gauge and sender
Remote E-stop button
Panel viewing window
Sound attenuated enclosure, Level 2
External emergency stop
Anti-condensation heater
Coolant heater
Lube oil sump heater
Wiring for canopy space heater
Jacket water heater
Battery heater
Radiator transition flange
Emergency vent pipe
Tank riser
209 and 394 gallon sub-base fuel tanks
5 Gallon fill containment
Seismic vibration isolators
PGS Test report @ 1.0 power factor
4 Hour factory test
PGS Test report @ 0.8 power factor
Generator test report
10, 25 and 35 dBA silencer systems
Overhead silencer mounting kit
Permanent magnet excitation (PMG) generator