Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Maximum Rating 80 ekW
Minimum Rating 80 ekW
Emissions/Fuel Strategy U.S. EPA Cert., Tier 3
Voltage 208 to 600 Volts
Duty Cycle Standby
Emissions/Fuel Strategy U.S. EPA Cert., Tier 3
Frequency 60 Hz
Maximum Rating 80 ekW
Minimum Rating 80 ekW
Speed 1800 rpm
Voltage 208 to 600 Volts
Aspiration Turbocharged
Bore 4.1in
Compression Ratio 16.7:1
Displacement 269in³
Engine Model C4.4, In-line 4, 4-cycle diesel
Fuel System Common Rail
Governor Type Mechanical, ADEM™A4
Stroke 5in
Dry Weight - Genset (maximum) 950lb
Height - Maximum 52.9in
Length - Maximum 82.6in
Width - Maximum 43.3in
Air cleaner; light duty with disposable element
Air cleaner
Radiator and cooling fan with guards
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Coolant drain line with valve
GCCP 1.2 Control panel
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
Circuit breaker, IEC, 3 pole, mounted in tower panel
Voltage regulator (single phase sensing)
IP23 Protection
Segregated low voltage (AC/DC) wiring panel
12 Leads
Tower panel, IP22, bottom cable entry
Mechanical and electrical governing system - model dependent
Lubricating oil
Oil drain line with valve
Includes lifting provision and drag points
Termination points for coolant and lube oil drain lines
Captive linear vibration isolators between base and engine-generator
Batteries
24V battery with rack and cables
Engine and alternator pre-paint, Caterpillar yellow
3 Phase sensing
Anti-condensation heater
R Frame auxilliary winding
Permanent magnet excitation (PMG)
Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
Low coolant level shutdown
Coolant heater
Low coolant temperature alarm
Earth fault (2 wire only)
Overload shutdown via breaker
Earth leakage (2 wire only)
Volt free contacts
Panel mounted audible alarm
Battery charger
GCCP 1.2 Control panel
Control panel heater
Voltage adjust potentiometer
Emergency stop with key
Speed adjust potentiometer
Sound attenuated Level 2 enclosure
High fuel level alarm
Open set narrow tankbase
Low fuel level alarm
Bunded fuel tank
Low fuel level shutdown
Compact skidbase for open set
Skidbase for CALG enclosure sets
Certification for CIS
Battery removal
Industrial silencer
Electronic governor
External single point lift - enclosure
Silencer installation kit
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
Stone guards/rad trans flange
Packing case - canopied set
Packing case - compact set